亚洲午夜精品久久久久久一区二区,人妻在客厅扒开腿被姧午夜福利,色婷婷一区二区三区AV免费看,凹凸人妻视频一二三区视频,AV中文懂色八戒

產(chǎn)品詳情
  • 名稱:實(shí)驗(yàn)動物腦內(nèi)酵素瞬間滅活性系統(tǒng)

  • 型號:Muromachi Microwave Fixation system MMW-05 (5kW)
  • 廠商:其它品牌
  • 文檔:
你添加了1件商品 查看購物車
簡單介紹:
微波固定系統(tǒng),該設(shè)備能快速“固定”大腦化學(xué)物質(zhì),通過微波照射使大腦內(nèi)的酶等化學(xué)物質(zhì)維持不變,使得研究在活體條件下進(jìn)行。系統(tǒng)能**測量 cAMP, cGMP, GABA, Acetylcholine, choline, DOPA, 5HTP, endorphin, prostaglandins, and catecholines 以及它們的代謝物。 微波固定系統(tǒng)通過一個專門的發(fā)射器將產(chǎn)生的微波能量傳
詳情介紹:

微波固定系統(tǒng) (*新型號)

(實(shí)驗(yàn)動物腦內(nèi)酵素瞬間滅活性系統(tǒng))
Muromachi Microwave Fixation system



 原理與特色:

1. 用微波加熱的方式使得神經(jīng)組織內(nèi)的酶(ENZYME)去活性,以避免死后變化
  (post-mortem changes)持續(xù)進(jìn)展。
2. 此法比用冷凍固定法要來得好:冷凍法需要10-90秒做深入冷凍去活性,這段
    期間,深部組織的死后變化(post-mortem changes)已經(jīng)在進(jìn)行,因腦表面
    的熱傳導(dǎo)轉(zhuǎn)差。微波法可在更短的時間內(nèi)完全去活性。
3. 可以測:
                   *  Acetylcholine乙酰膽堿
             
  * 
Choline 膽堿
               * 
Cyclic AMP 環(huán)腺苷酸
               * 
Cyclic GMP 環(huán)林鳥苷
               * 
GABA  伽馬氨基丁酸              
               * 
DOPA 多巴(二羥基苯丙氨酸)
               * 
5-HTP 5-羥色胺酸
               * 
Serotonin 血清素
               * 
Endorphin 內(nèi)啡肽
               * 
Prostaglandin 前列腺素
               *  
Catecholamines and their metabolites 兒茶酚胺及其代謝物
               *  Phosphorylated Proteins 磷酸化蛋白質(zhì)

微波固化可以達(dá)到下列標(biāo)準(zhǔn):

1. 可將溫度升至75-90攝氏度,使腦部快速固定。
2. 微波能量可有效集中在動物的頭部。
3. 各種動物間都可以達(dá)到相同的結(jié)果。
4. 對操作人員具備嚴(yán)格的保護(hù),此設(shè)備相當(dāng)簡單**
5.  CE認(rèn)證,國際規(guī)定家用微波設(shè)備微波泄漏不得超越5毫瓦/立方厘米,
     我們的設(shè)備**標(biāo)準(zhǔn)遠(yuǎn)遠(yuǎn)低于此,不超過1毫瓦/立方厘米。


新增特性:

1. 所有控制均位于前面板觸摸屏幕上
2. 數(shù)字化使得電源級別設(shè)置更容易,重復(fù)性更強(qiáng)
3. 客戶處電壓不穩(wěn)波動性得到很好的控制
4. 采用風(fēng)冷裝置,無需水冷,升降溫時間控制速度快
5.  整體重量變輕,僅為103公斤




1. 波導(dǎo)管            2. 應(yīng)用管頭                      3. 應(yīng)用管門閉      
4. 觸摸屏            5. 主開關(guān)(斷路器)        6. 空氣入口
7. 腳輪               8. 應(yīng)用管帽                       9. 應(yīng)用管門開關(guān)
10. 應(yīng)用管門     11. 應(yīng)用管頭室                  12. 空氣出口
13. 電源線接口

規(guī)格
振蕩器 Panasonic Magnetron 2M265-M11
微波輸出 5kW max. (2-5 千瓦變頻)
震蕩頻率 2.450±30MHz
冷卻要求 空氣冷卻
水流量  每分鐘兩升
暴露時間 0.01-9.99秒 (0.01秒步進(jìn))
暫停時間 3 分鐘
能量功耗 8 千瓦  
頻率 50 或者 60 Hz
電源要求 190-240 VAC 30A 3相 或者
380-440 VAC 20A 3相
外形尺寸 750 W x 550 D x 1,275 H 厘米
重量 大約 103公斤

 






 

 

APPLICATOR HEAD

適用的動物管

TAW-174P WJM-24 for Mouse 15-20g
WJM-28 for Mouse 20-40g
TAW-424SP WJR-S for Rat 150-250g
TAW-424MP WJR-M for Rat 250-400g
WJR-L for Rat 400-500g




水套式動物管(左側(cè)的是大鼠固定器,右側(cè)的是老鼠固定器)


標(biāo)準(zhǔn)系統(tǒng)包括:

Applicator Head ( Any one from the list ) 1
Animal Holder ( Any one from the list ) 1
Dust Cover 1

發(fā)表文獻(xiàn):

Unambiguous assignment of the H3S and H3R deuterations of cerebral (2-13C) glutamate by 13C NMR at 18.8 tesla

TB Rodrigues, IR Violante, S … - Magnetic Resonance in …, 2010 - interscience.wiley.com
... At the end of the infusions, cerebral metabolism was arrested using a 5- kW microwave
fixation system, the brain being rapidly removed from the skull and immediately frozen in liquid N2. ...

Brain glutamine synthesis requires neuronal-born aspartate as amino donor for glial glutamate formation

B Pardo, TB Rodrigues, L Contreras, M … - Journal of Cerebral …, 2010 - nature.com
... regulated circulating water bath. Fifteen minutes after 13 C-label administration, the
metabolism was arrested using a high-power (5 kW) focused microwave fixation system
The brain was ...

Delayed Increase of Brain Noradrenaline After Acute Footshock Stress in Rats

T Shinba, N Ozawa, M Yoshii, K Yamamoto - Neurochemical research, 2010 - Springer
... 4.5–5 kW, 1.4 s) using a small animal microwave applicator...
Immediately after microwave radiation, the brains were harvested and put onto an ice-chilled
Petri dish ... Moroji T, Takahashi T, Ogura K, Toishi T, Arai S (1977) Rapid fixation of rat ...

Altered Affect, Monoamine Transmitters and Bioenergetic Homeostasis of Alpha-synuclein-transgenic Mice, in the Presence and Absence of Endogenous Alpha- EM Cumyn - 2010 - tspace.library.utoronto.ca
... 36 3.7 Open field test..... 37 3.8 Microwave fixation and dissection of brain tissue.....
37 3.9 Fresh dissection and flash-freezing of brain tissue..... 40 ...

Brainstem Concentrations of Cholesterol are not Influenced by Genetic Ablation of the Low-Density Lipoprotein Receptor

AY Taha, CT Chen, Z Liu, JH Kim, HTJ Mount, … - Neurochemical …, 2009 - Springer
... At 7 weeks of age, the mice were euthanized with a high-energy head-focused microwave
fixation system (6 kW, 0.88–0.99 s, Muromachi brain fixation system in order to stop brain lipid metabolism [14, 15]. ...

Detection of reduced GABA synthesis following inhibition of GABA transaminase using in vivo magnetic resonance signal of [13C] GABA C1

J Yang, C Johnson, J Shen - Journal of neuroscience methods, 2009 - Elsevier
... After in vivo MRS data acquisition of gabaculine-treated rats infused with [2,5- 13 C 2 ]glucose
and unlabeled glucose, the rats were euthanized using a microwave fixation device (Model
TNW-6402C, 5 kW, 1.5 s). Subsequently, the rat ... 



 